gas blenders
Beer Gas 101 |
Gas Settings
Trumix 100 & Trumix
100 High Flow
Used for single blend long draw beer systems.
Best for dispensing one style beer. Blends CO2 and N2 to your
specifications.
|
 |
| Size: |
9.5" wide (including mounting flanges
x 10" high x 4.5" deep) |
| Hook-Up: |
Two inlet lines and one outlet line. |
| Fittings: |
Panel comes with standard 1/4" female NPT fittings. Hose
barbs available at no additional costs. Specify size: 1/4",
5/16", and 3/8". |
| Accuracy and Flow Range: |
Maintains accuracy of +/- 2% of full scale or better within
the flow range of .4 to 40 liters per minute (.85 to 85 cubic
feet per hour). |
| Standard Blender: |
Up to 15 kegs/hr. dispensed. |
| High Flow Blender: |
Up to 30 kegs/hr. dispensed. Used for
systems requiring only one blend of C02 and N2 that operate with
higher than usual gas flow. |
| Inlet Pressures: |
55-150 psi, however, panel can be set
to match any conditions. Blender tuned at inlet pressure of existing
system. Standard 55 and 70 psi. |
Outlet Pressures:
|
Adjustable outlet pressures of 0-60 psi.
The maximum outlet pressure will always be 10 psi lower than
the lowest inlet pressure. The panel can also be ordered with
outlet pressure set to custom ranges.
|
| |
|
Trumix 200 & Trumix
200 High Flow
Used for systems that dispense more than
one type of beer requiring two separate blends of CO2 and N2.
|
 |
| Size: |
9.5" wide (including mounting flanges
x 10" high x 4.5" deep) |
| Hook-Up: |
Two inlet lines and two outlet lines. |
| Fittings: |
Panel comes with standard 1/4" female NPT fittings. Hose
barbs available at no additional costs. Specify size: 1/4",
5/16", and 3/8" |
| Accuracy and Flow Range: |
Maintains accuracy of +/- 2% of full scale or better within
the flow range of .4 to 40 liters per minute (.85 to 85 cubic
feet per hour). |
| Standard Blender: |
Up to 30 kegs/hr. (15 kegs/hr. per blend)
dispensed. |
| High Flow Blender: |
Up to 60 kegs/hr.(30 kegs/hr. per blend)
dispensed. Used for systems requiring two blends of C02 and N2
that operate with higher than usual gas flow. |
| Inlet Pressures: |
55-150 psi, however, panel can be set
to match any conditions. Blender tuned at inlet pressure of existing
system. Standard 55 and 70 psi. |
Outlet Pressures:
|
Adjustable outlet pressures of 0-60
psi. The maximum outlet pressure will always be 10 psi lower
than the lowest inlet pressure. The panel can also be ordered
with outlet pressure set to custom ranges.
|
| |
|
Beer Gas 101 | Gas