gas blenders

Trumix 100 & Trumix 100 High Flow
Used for single blend long draw beer systems. Best for dispensing one style beer. Blends CO2 and N2 to your specifications.

Size: 9.5" wide (including mounting flanges x 10" high x 4.5" deep
Hook-Up: Two inlet lines and one outlet line.
Fittings: Panel comes with standard 1/4" female NPT fittings. Hose barbs available at no additional costs. Specify size: 1/4", 5/16", and 3/8".
Accuracy and Flow Range: Maintains accuracy of +/- 2% of full scale or better within the flow range of .4 to 40 liters per minute (.85 to 85 cubic feet per hour).
Standard Blender: Up to 15 kegs/hr. dispensed.
High Flow Blender: Up to 30 kegs/hr. dispensed. Used for systems requiring only one blend of C02 and N2 that operate with higher than usual gas flow.
Inlet Pressures: 55-150 psi, however, panel can be set to match any conditions. Blender tuned at inlet pressure of existing system. Standard 55 and 70 psi.

Outlet Pressures:

Adjustable outlet pressures of 0-60 psi. The maximum outlet pressure will always be 10 psi lower than the lowest inlet pressure. The panel can also be ordered with outlet pressure set to custom ranges.

   

Trumix 200 & Trumix 200 High Flow
Used for systems that dispense more than one type of beer requiring two separate blends of CO2 and N2.

Size: 9.5" wide (including mounting flanges x 10" high x 4.5" deep
Hook-Up: Two inlet lines and two outlet lines.
Fittings: Panel comes with standard 1/4" female NPT fittings. Hose barbs available at no additional costs. Specify size: 1/4", 5/16", and 3/8"
Accuracy and Flow Range: Maintains accuracy of +/- 2% of full scale or better within the flow range of .4 to 40 liters per minute (.85 to 85 cubic feet per hour).
Standard Blender: Up to 30 kegs/hr. (15 kegs/hr. per blend) dispensed.
High Flow Blender: Up to 60 kegs/hr.(30 kegs/hr. per blend) dispensed. Used for systems requiring two blends of C02 and N2 that operate with higher than usual gas flow.
Inlet Pressures: 55-150 psi, however, panel can be set to match any conditions. Blender tuned at inlet pressure of existing system. Standard 55 and 70 psi.

Outlet Pressures:

Adjustable outlet pressures of 0-60 psi. The maximum outlet pressure will always be 10 psi lower than the lowest inlet pressure. The panel can also be ordered with outlet pressure set to custom ranges.