Glacier GLYCOL CHILLER SERIES M

1/3 HP Glycol Chiller MODEL M4301-EP

Horsepower: 1/3 Refrigeration: R134a Freon
One Glycol Vertical Pump
Dimensions: 22”H x 26”W x 18”D
Electrical Specs: 115V/60/1, 7.0 Amps, Plug Type (NEMA#) 5-15P
Glycol Bath Capacity: 5 Gallons BTU/hr: 2,300
Maximum Trunkline Line Run: 75 ft.

  • Steel housing, coated in baked enamel for durability and clean appearance.
  • Digital thermostat for accurate glycol bath temperature.
  • Pump and motor are mounted on the exterior for easy access and repair.

 

1/3 HP Glycol Chiller MODEL M4301

Horsepower: 1/3 Refrigeration: R134a Freon
One Glycol Recirculating Pump
Dimensions: 31”H x 26”W x 19”D
Electrical Specifications: 115V/60/1, 12.9 Amps, 20 Amp Service
Glycol Bath Capacity: 11.5 Gallons BTU/hr: 2600
Maximum Trunkline Line Run: 125 ft.

  • Steel housing, coated in baked enamel for durability and clean appearance.
  • Digital thermostat for accurate glycol bath temperature.
  • Pump and motor are mounted on the exterior for easy access and repair

 

1/3 HP Glycol Chiller MODEL M4301D

Horsepower: 1/3 Refrigeration: R134a Freon
Two Glycol Recirculating Pumps
Dimensions: 40”H x 24”W x 40”D
Electrical Specifications: 115V/60/1, 21.5 Amps, 30 Amp Service
Glycol Bath Capacity: 11.5 Gallons BTU/hr: 2600
Maximum Trunkline Line Run: 125 ft.

  • Steel housing, coated in baked enamel for durability and clean appearance.
  • Digital thermostat for accurate glycol bath temperature.
  • Pump and motor are mounted on the exterior for easy access and repair

 

1/2 HP Glycol Chiller MODEL M4302

Horsepower: 1/2 Refrigeration: R134a Freon
One Glycol Recirculating Pump
Dimensions: 40”H x 24”W x 40”D
Electrical Specifications: 115V/60/1, 15.3 Amps, 20 Amp Service
Glycol Bath Capacity: 11.5 Gallons BTU/hr: 3400
Maximum Trunkline Line Run: 250 ft.

  • Steel housing, coated in baked enamel for durability and clean appearance.
  • Digital thermostat for accurate glycol bath temperature.
  • Pump and motor are mounted on the exterior for easy access and repair.

 

1/2 HP Glycol Chiller MODEL M4302D

Horsepower: 1/2 Refrigeration: R134a Freon
Two Glycol Recirculating Pumps
Dimensions: 40”H x 24”W x 40”D
Electrical Specifications: 115V/60/1, 21.5 Amps, 30 Amp Service
Glycol Bath Capacity: 11.5 Gallons BTU/hr: 3400
Maximum Trunkline Line Run: 250 ft.

  • Steel housing, coated in baked enamel for durability and clean appearance.
  • Digital thermostat for accurate glycol bath temperature.
  • Pump and motor are mounted on the exterior for easy access and repair


 

1 HP Glycol Chiller MODEL 4305D

Horsepower: 1.0 Refrigeration: R22a Freon
Two Glycol Recirculating Pumps
Dimensions: 41”H x 25”W x 40”D
Electrical Specs: 208-230V/60/1, 11 Amps, 20 Amp Service
Glycol Bath Capacity: 11.5 Gallons BTU/hr: 7200
Maximum Trunkline Line Run: 500 ft.

  • Steel housing, coated in baked enamel for durability and clean appearance.
  • Digital thermostat for accurate glycol bath temperature.
  • Pumps and motors are mounted on the exterior for easy access and repair